English
Boiler & Tube, Inc.
| ||||||||||||
|
|
"CP" Type The "CP" boiler consists of two parallel drums,
configured such that the upper drum is considerably longer than the lower drum.
In addition the boiler has two (2) lower sidewall headers that run the complete
length of the boiler setting and help to configure the sidewalls of the boiler's
furnace. The "CP" type boiler has been consistently used for over 70 years
in typical solid fuel fired configurations for both saturated and superheated
steam boilers. The original boilers of this design consisted of tube and
tile construction. However, due to engineering
advancements in waterwall membrane construction, the furnace sidewalls are now
of the membrane design. Typical boilers with tube and tile construction
were usually field erected. Boilers with membrane design now are
constructed similar to Package Watertube boilers, and are fabricated and
assembled in the shop and shipped as modular units.
|
|
|